The slide is used for test purposes, must meet various requirements and is manufactured in series.

Requirements:

  • Non-magnetic series, titanium shafts and ceramic balls, brass hardware
  • No anodize on base, carriage and endcaps
  • Vent holes added to DA-2 carriage, no blind holes on DA-1 base
  • 2x 5mm thru holes added to the DA-2 carriage
  • Use brass retainers instead of delrin – temperature resistance above 100°C
  • With 6 preload screws for optimum adjustment